Smart Wallbox AC Charger
Dual‑port wallbox with app & OCPP control, multi‑network connectivity, and full‑stack safety for home or commercial use.


kW
Max three‑phase output—full battery before your coffee cools.
IP54 / IK08
Weather‑sealed & impact‑proof for year‑round driveway duty
Years Experience
Powerful, Flexible, Future‑Proof
With 7.4 kW for single‑phase homes and 22 kW for three‑phase setups, the Series Wallbox grows with your panel, your solar array, and your next EV.
Adjustable Current
Dial in 10 A, 13 A, 16 A, or 32 A to match any breaker.
Smart Scheduling
Auto‑start during off‑peak hours and track savings in real time.
Safety You Can See—and Trust

From built‑in PEN fault detection to encrypted firmware, every layer of the X‑Series Wallbox is engineered to protect your home, your car, and your data.
PEN Fault Protection
No earth rod needed—built‑in PEN detection slashes install time and cost.
Dual Residual Current Detection
AC 30 mA Type A + DC 6 mA sensors cut power in milliseconds.
LED Status Ring
360° colors show standby, charging, or fault—clearly visible day and night.
Secure Firmware
Signed OTA updates, encryption, and rolling security logs block tampering
Wi‑Fi & Ethernet on board, 4G optional
OCPP 1.6 JSON certified—ready for any backend
RFID tap‑to‑start + remote unlock via app
UK Smart Charge Point Regulations compliant, tamper alerts included
Always Online, Always Compliant
Specification
Technical Specification | |||
Model Number | XEVC-AC-4-7AEU1 | XEVC-AC-4-11AEU1 | XEVC-AC-4-22AEU1 |
AC power | 1P+N+PE | ||
Voltage (V) | AC 220 - 240V | ||
Frequency (Hz) | 50/60 | ||
Operating Temperature | -25°C to +50°C | ||
Rated Current | Max 32A (6-32A Adjustable) | ||
Incoming Cable Terminals | 3 x 10mm² terminals | ||
Over Current Protection | Recommended 36A | ||
Charging Connector | IEC 62196 (Type 2) | ||
AC & DC Fault Protection | 30mA Type A+ 6mA DC sensitive protective device |
Have Question?
Everything You Need to Know Here Today
220‑240 V AC single‑phase (L + N + PE), 50/60 Hz. Use a 36 A C‑curve breaker and ≥ 3 × 6 mm² cable; terminals accept up to 10 mm².
Yes. Hardware dial (6‑32 A) is standard; with the TUYA App or OCPP 1.6 J options you can adjust current or schedules via app / backend API.
Yes. 30 mA Type A + 6 mA DC detection is integrated, so no external Type B RCD is required.
TUYA gives quick Wi‑Fi/Bluetooth setup for small sites; OCPP 1.6 J adds Ethernet/4G and full backend billing, load‑balancing & roaming. They can be ordered together.
With OCPP you can use backend load balancing. For onsite master‑slave sharing, request the “Smart Cluster” firmware when ordering.
Standard is a Type 2 socket; a 5 m tethered‑cable version is available on request.
Yes. Select the “PEN protection (UK)” option to comply with BS 7671 Amd 2 on TN‑C‑S supplies—no earth rod needed.